Benefit from our 30 years of experience in the fields of nuclear, chemical warfare, military, civil defence, petrochemical explosion and ground acceleration equipment consultancy, design, manufacture and field installation

GENERAL
Protection against the impact of fragments and debris
Absorption of nuclear radiation and heat
Protection against nuclear fall out and toxic gases

STANDARD DATA
Type Frame Dimension Protection Door Weight
Inner Width Inner Heigth Level Thickness No conc
mm
mm
Armoured Door PT
800
1,850
3
200
205
Armoured Door PT
1,000
1,850
3
200
250
Armoured Door PT
1,400
2,200
3
200
480
Armoured Door PT
600
1,200
3
200
170
Armoured Cover PD
600
800
3
200
140
Pressure Door DT
800
1,850
0.3
100
115
Pressure Door DT
1,000
1,850
0.3
100
125
Pressure Door DT
1,400
2,200
0.3
200
190
Armoured Double PTO
2,400
2,100
1
200
670
Leaf Door PTO
2,400
2,100
3
250
1,110

RESISTANCE AGAINST MECHANICAL LOADS

To estimate the protection capacity in respect of dynamic loads, the following data can be used as a basis :-


AIR BLAST
Type
Exterior
Load Capacity
Rebound
Dynamic Pressure Load and Static Ulrimate Resistance Pdyn = ru
Dynamic Impulse Load
Interior/Exterior Resistance
PT
1
MN/m2
10
kN/m2
> 20%
PD
1
MN/m2
3
kN/m2
100%
PTO SG1
0.25
MN/m2
3
kN/m2
> 20%
PTO SG3
1
MN/m2
10
kN/m2
> 20%
DT
80
kN/m2
300
N/m2
100%

GROUND SHOCK

Units will resist ground shock/acceleration forces up to 80 m/s2

Fixing Instructions for Shelter Closure

Standardized shuttering device (1) for shelter doors, also wall shuttering can be used.

The door body with its frame, has to be placed vertically and wedged accurately to the wall shuttering boards (2) the door must not be separated from its frame.

The wall has to be cast first. The door should not be cast until the concrete in the wall is sufficiently cured. The door must be cast in the closed position.

A minimum gap of 4cm has to be provided between the top of the door body and the ceiling, and also between the bottom of the door body and the finished floor.